7
Technical data
General technical data
Weight
EAGLE..-.........999S..
EAGLE..-.........999T..
EAGLE..-.........999E..
EAGLE..-.........9H2S..
EAGLE..-.........9H2E..
EAGLE..-.........9H2T..
Power supply
See "Requirements for connecting electrical wires" on page 9.
Supply voltage
Nominal voltage DC
with the
Voltage range DC incl.
characteristic
maximum tolerances
value CC
Voltage range DC in
Hazardous Locations (Class I,
Division 2) incl. maximum
tolerances
Connection type
Power loss buffer
Overload current protection on
the device
Back-up fuse
Peak inrush current
Power supply
See "Requirements for connecting electrical wires" on page 9.
Supply voltage
Nominal voltage AC
with the
Voltage range AC incl.
characteristic
maximum tolerances
value K9
Voltage range AC in
and KK
Hazardous Locations (Class I,
Division 2) incl. maximum
tolerances
Nominal voltage DC
Voltage range DC incl.
maximum tolerances
Voltage range DC in
Hazardous Locations (Class I,
Division 2) incl. maximum
tolerances
Connection type
Power loss buffer
Overload current protection on
the device
Back-up fuse
Peak inrush current
Installation EAGLE20/30
Release 12 03/2021
approx. 2.65 lb (1.2 kg)
approx. 3.31 lb (1.5 kg)
approx. 4.19 lb (1.9 kg)
24 V DC ... 48 V DC
18 V DC ... 60 V DC
22 V DC ... 52 V DC
2-pin terminal block
>10 ms at 20.4 V DC
Non-replaceable fuse
Nominal rating:
Characteristic:
<4 A
110 V AC ... 230 V AC, 50 Hz ... 60 Hz
88 V AC ... 265 V AC, 47 Hz ... 63 Hz
99 V AC ... 253 V AC
60 V DC ... 250 V DC
48 V DC ... 320 V DC
54 V DC ... 275 V DC
3-pin terminal block
>10 ms at 98 V AC
Non-replaceable fuse
Nominal rating:
Characteristic:
<3.5 A
6.3 A
slow blow
min. 2.5 A
max. 20 A
slow blow
47