5. Technical data

General data
Operating voltage
Rated voltage range DC
Max. voltage range DC
Buffer time
Potential difference between input
voltage and housing
Current consumption at 24 V DC
Dimensions W x H x D
Weight
Ambient temperature
Storage temperature
Atmospheric pressure
Protection type
Protection against shock and foreign particles Full shock protection, impenetrable to dust
Water protection
Interference proof
Discharge of static electricity
Contact discharge
Air discharge
Electromagnetic fields
Fast transients
Surge voltage symmetrical
Surge voltage asymmetrical
Cable-based RF faults
EMC emitted immunity
EN 55022
FCC 47 CFR Part 15
Stability
Vibration
Shock
Certifications
cUL 508 / CSA 22.2 No.14-M91
Network size
TP port 10BASE-T/100BASE-TX
Length of a twisted pair segment
Interfaces
5 TP ports
Displays
Equipment status
Port status
Scope of delivery
IP67 Switch OCTOPUS 5TX-EEC incl.
Order number
IP67 Switch OCTOPUS 5TX-EEC
IP67 Switch OCTOPUS 5TX-EEC with QoS 942 052-001
Accessories
Pocket Guide
Hirschmann Automation and Control GmbH
Stuttgarter Straße 45-51
D-72654 Neckartenzlingen
Germany
Tel.: ++49 / 1805 / 14-1538
Fax: ++49 / 7127 / 14-1551
E-Mail: HAC.Support@Belden.com
Internet: http://www.beldensolutions.com
Printed in Germany
Subject to alterations
12 V DC to 24 V DC Safety extra-low voltage (SELV)
Relevant for North America: NEC Class 2 power source max. 5 A
min. 9.0 V DC to max. 32 V DC
(Not applicable under UL regulations)
min. 10 ms at 20.4 V DC
Potential difference to input voltage, +24 V DC: 32 V DC
Potential difference to input voltage, ground: -32 V DC
2.4 W maximum; 8.2 Btu (IT)/h
60 mm x 126 mm x 31 mm
210 g
Surrounding air - 40 ºC to + 85 ºC
Note: Following UL508 requirements the ambient temperature is restricted to 60 °C.
Surrounding air - 40 ºC to + 85 ºC
up to 2000 m (795 hPa, higher altitudes on demand)
IP 67, according to EN 60529
Protected against water penetration, during submersion under
specified pressure and time conditions
EN 61000-4-2 Test level 2
EN 61000-4-2 Test level 3
EN 61000-4-3 Test level 3
EN 61000-4-4 Test level 3
EN 61000-4-5 Test level 2
EN 61000-4-5 Test level 3
EN 61000-4-6 Test level 3
Class A
Class A
IEC 60068-2-6 Test FC, testing level in line with EN 61131-2:2007
IEC 60068-2-27 Test Ea, testing level in line with EN 61131-2:2007
E175531
100 m (328 ft) maximum
M12 sockets (4-pin, D coding), 10/100 MBit/s
1 x green LED
P – power, supply voltage present
5 x green LEDs
DA/STAT – data, link status
covers for sealing unused ports
labels, description and operating instructions
943 892-001