General technical data
Dimensions 
W x D x H
Weight
Power supply
Overload current
protection at input
Insulation voltage
between operating
voltage connections
and housing
"FAULT"
signal contact
Environment
Operating
temperature
Pollution degree
Protection classes
a. Only use SFP modules with the "EEC" extension.
34
RS20-08..., RS20-09..., RS30-0802
RS20-16..., RS20-17..., RS30-1602
RS20-24..., RS20-25..., RS30-2402
RS20-08..., RS20-09..., RS30-0802
RS20-16..., RS20-17..., RS30-1602
RS20-24..., RS20-25..., RS30-2402
Operating voltage
Rated voltage range DC
Rated voltage range AC
Max. voltage range DC
Max. voltage range AC
Switching current
Switching voltage
Storage temperature
(ambient air)
Humidity
Air pressure
Standard
Extended
Laser protection
Degree of protection
74 mm x 131 mm x 111 mm
110 mm x 131 mm x 111 mm
110 mm x 131 mm x 111 mm
410 g
600 g
650 g
12 to 48 V DC
24 V AC
Safety extra-low voltage (SELV),
redundant inputs disconnected.
Relevant for North America: NEC
Class 2 power source max. 5A.
min. 9.6 to max. 60 V DC
min. 18 to max. 30 V AC
(Not applicable under UL
regulations)
Non-replaceable fuse
800 V DC
Protective elements limit the
insulation voltage to 90 V DC (1 mA)
max. 1 A, SELV
max. 60 V DC or max. 30 V AC,
SELV
Standard: -40 °C to +70 °C 
(-40 °F to +158 °F)
Extended: -40 °C to +85 °C
10% to 95%
(non-condensing)
Up to 2000 m (795 hPa), higher
altitudes on request
0 °C to +60 °C (+32 °F to +140 °F)
−40 °F ... +158 °F
a
(−40 °C ... +70 °C)
2
Class 1 according to IEC 60825-1
(2007)
IP 20
RS20/RS30...U
Release 01 06/2012

Advertisement

Table of Contents
loading