6

Technical data

General technical data
Weight
EAGLE..-.........999S..
EAGLE..-.........999T..
EAGLE..-.........999E..
Power supply
Operating
Nominal voltage DC
voltage
Voltage range DC
characteristic
value C
Connection type
Power failure bypass
Overload current protection at
input
Back-up fuse
Peak inrush current
Power supply
Nominal voltage AC
Operating
Voltage range AC
voltage
Nominal voltage DC
characteristic
Voltage range DC
value K
Connection type
Power failure bypass
Overload current protection at
input
Back-up fuse
Peak inrush current
Climatic
Ambient temperature
conditions
during operation
Humidity
Air pressure
Climatic
Ambient temperature
conditions
Humidity
during storage
Air pressure
"FAULT"
Switching current
signal contact
Switching voltage
Pollution degree
Protection
Laser protection
classes
Degree of protection
a. Only use SFP modules with the "EEC" extension.
b. +185 °F (+85 °C) for 16 hours (tested acc. to IEC60068-2-2)
Installation EAGLE20/30
Release 05 10/2013
Relevant for North America: Class 2
ca. 1,2 kg
ca. 1,5 kg
24 V ... 48 V Class 2
18 V ... 60 V (incl. max. tolerances)
Class 2
2-pin terminal block
> 10 ms at 20.4 V DC
Non-replaceable fuse
Nominal rating:
Characteristic:
< 4 A
110 V ... 230 V, 50 Hz ... 60 Hz
88 V ... 265 V, 47 Hz ... 63 Hz
60 V ... 250 V
48 V ... 320 V (incl. max. tolerances)
3-pin terminal block
> 10 ms at 98 V AC
Non-replaceable fuse
Nominal rating:
Characteristic:
< 3.5 A
Devices with operating temperature
characteristic value S (standard):
0 °C ... +60 °C (+32 °F ... +140 °F)
Devices with operating temperature
characteristic value E and T (extended):
a,b
−40 °C ... +70 °C
10% ... 95%
(non-condensing)
minimum 700 hPa (≈ +9842 ft (+3000 m))
maximum 1060 hPa (≈ −1312 ft (−400 m))
−40 °F ... +185 °F (−40 °C ... +85 °C)
10% ... 95%
(non-condensing)
minimum 700 hPa (≈ +9842 ft (+3000 m))
maximum 1060 hPa (≈ −1312 ft (−400 m))
max. 1 A, SELV
max. 60 V DC or max. 30 V AC, SELV
2
Class 1 in compliance with IEC 60825-1
IP 30
6.3 A
slow blow
2.5 A
slow blow
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eagle20-0400 series

Table of Contents