Technical data

General technical data
Dimensions
W × H × D
Weight
Power supply
Overload current protection at input
Insulation voltage between operating voltage connections
and housing
"FAULT"
signal contact
Environment
Surrounding air
temperature
Pollution degree
Protection classes
a. If you are using SFP modules without the "EEC" extension, then an operating temperature
range from 0 °C to +60 °C applies for your device
28
RSB20-0800T1T1
RSB20-0800M2M2, RSB20-
0800S2S2 and RSB0900...
RSB20-0800T1T1
RSB20-0800M2M2, RSB20-
0800S2S2 and RSB0900...
Operating voltage
Rated voltage range DC
Max. voltage range DC
Switching current
Switching voltage
Storage temperature
(ambient air)
Humidity
Air pressure
Standard
a
Extended
Laser protection
Protection class
47 mm x 131 mm x 111 mm
(1.85 in x 5.16 in x 4.37 in)
74 mm x 131 mm x 111 mm
(2.91 in x 5.16 in x 4.37 in)
400 g (0.881 lb)
410 g (0.904 lb)
12 to 24 volts DC, max. 5 A
Safety extra-low voltage (SELV),
redundant inputs disconnected.
Relevant for North America: NEC
Class 2 power source max. 5A.
min. 9.6 to max. 32 V DC
(Not applicable under UL
regulations)
Non-replaceable fuse
800 V DC
Protective elements limit the
insulation voltage to 45 V DC (1mA)
max. 0.5 A AC / 0.3 A DC, resistive
load
max. 60 V DC or max. 30 V AC,
SELV
Standard: -40 °C to +70 °C
(-40 °F to +158 °F)
Extended: -40 °C to +85 °C
10% to 95%
(non-condensing)
Up to 2000 m (795 hPa), higher
altitudes on request
0 °C to +60 °C (+32 °F to +140 °F)
-40 °C to +70 °C
acc. to UL and CSA: max. +60 °C
2
Class 1 according to EN 60825-1
(2007)
IP 20
(see page 32 "Accessories".)
RSB20
Release 20 09/11