Use And Configuration - Sensopart FT 50 RLA 70-L8 Mounting And Operating Instructions

Distance sensor
Table of Contents

Advertisement

Available languages

Available languages

Connection
Colour
1 (WH)
White
2 (BN)
Brown
3 (GN)
Green
4 (YE)
Yellow
5 (GY)
Grey
6 (PK)
Pink
7 (BU)
Blue
8 (RD)
Red
Once power supply has been connected, the FT 50 RLA is ready for operation after a short stand-by delay
(< 300 ms).
INFORMATION
For maximum precision, please allow for a heating period (approx. 15 minutes).
7

Use and configuration

The sensor has different operating modes and functions.
Sensor configuration can be carried out via the control panel using the
CAUTION
Push buttons only with finger! Do not use sharp objects!
With FT 50 RLA ... S1 (with RS485 interface) it is also possible to adjust the sensor functions via the serial interface.
48
Use
RS485 Data+ (Y/A)
+ U
B
As signal output Q
or input with optional input function (see
1
chapter 7 „Use and configuration")
As signal output Q
or switching function "good target" (detec-
2
table object in measuring range)
RS485 Data- (Z/B)
Q
+ analogue measurement
A
- U
B
Q
- analogue mass
A
SET
and
keys.
FT 50 RLA Disctance sensor - GB - 068-13671 - 20.04.2009-05
Mounting and
operating instructions
Remark
S1 version only
Q
1
Q
or Good Target
2
S1 version only

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ft 50 rla 70-s1l8Ft 50 rla 220-l8Ft 50 rla 220-s1l8

Table of Contents