Set Q1 As Control Input For Laser On / Off; Averaging - Sensopart FT 50 RLA 70-L8 Mounting And Operating Instructions

Distance sensor
Table of Contents

Advertisement

Available languages

Available languages

Example telegram
(in the example, the sensor has the address 1)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4. Byte
Check sum
8.5.5
Set Q
as control input for laser ON / OFF
1
Command (Byte 3): decimal 69; hexadecimal 0x45
Parameter:
no
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
Used to switch laser beam on and off. Laser beam is ON when Q
OFF. Last measured value remains. When reactivated, the response time is prolonged according to the set mean
value.
Example telegram
(in the example, the sensor has the address 1)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4. Byte
Check sum
8.5.6

Averaging

Command (Byte 3): decimal 66; hexadecimal 0x42
Parameter:
Configuration
D0 = 1 : 0,4 ms (no averaging)
D1 = 1 : 4 ms (10 measured values)
D2 = 1 : 40 ms (100 measured values)
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
The measurement result (output signal) is smoothed by averaging. The measured values are continuously stored in a
memory and the mean value is formed. The number of measured values used for averaging is set here.
68
Decimal
Hex.:
129
81
4
04
84
54
81
51
Decimal
Hex.:
129
81
4
04
69
45
64
40
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Check sum
= +U
. As long as Q
1
B
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Check sum
Parameter format
7 bit data byte
FT 50 RLA Disctance sensor - GB - 068-13671 - 20.04.2009-05
Mounting and
operating instructions
Decimal
Hex.:
129
81
4
04
89
59
92
5C
= - U
, the laser beam is
1
B
Decimal
Hex.:
129
81
4
04
89
59
92
5C