Example telegram
(in the example, the sensor has the address 1, the key lock is active)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4. Byte
Data
5. Byte
Check sum
8.5.16

Permanent storage of configurations

Command (Byte 3): decimal 83; hexadecimal 0x53
Parameter:
no
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
Sensor settings are stored in the EEPROM (they thus remain saved even after the power supply has been discon-
nected).
Example telegram
(in the example, the sensor has the address 1)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4 Byte
Check sum
8.5.17

Set Q1 input

Command (Byte 3): decimal 81; hexadecimal 0x51
Parameter:
D0 = 0: set Q
D0 = 1: set Q
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
Q
input is set via the software. The functions which depend on the status of the input (e.g. Q1 as trigger input or
1
autom. zero) can thus be controlled via the software.
FT 50 RLA Disctance sensor - GB - 068-13671 - 20.04.2009-05
Decimal
Hex.:
129
81
5
05
86
56
1
01
83
53
Decimal
Hex.:
129
81
4
04
83
53
86
56
low
1
high
1
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Check sum
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Check sum
Parameter format
7 bit data byte
Decimal
Hex.:
129
81
4
04
89
59
92
5C
Decimal
Hex.:
129
81
4
04
89
59
92
5C
73