Finalizing the Installation

Approved Vent

Rear Vent Configurations

Horizontal Terminations: use 8" (203mm) diameter Dura-Vent Model Direct-Vent Pro*.
Vertical Terminations: use 8" (203mm) diameter Dura-Vent Model Direct-Vent Pro* for the initial
horizontal run and 90° upward elbow. Then attach the 8" (203mm) to 6-5/8" (168mm) reducer (Travis
part # 98900165) to the elbow. Use 6-5/8" (168mm) diameter for the remaining vent.

Top Vent Configurations

Horizontal Terminations: use 8" (203mm) diameter Dura-Vent Model Direct-Vent Pro*.
Vertical Terminations: Use 6-5/8" (168mm) diameter Dura-Vent Direct-Vent Pro*. Attach the 8"
(203mm) to 6-5/8" (168mm) reducer (Travis part # 98900165) to the fireplace.
* Other vent may be approved with this fireplace. Check with the vent manufacturer for details.

Termination

Always use the high-wind cap (part # 58DVA-HC, 58DVA-VCH, 46DVA-VCH).

Vent Installation

Installation instructions for Dura-Vent may be found at www.duravent.com
Slide the vent sections together and turn 1/4 turn until the sections lock in
place.
Screws are not required to secure the vent. However, three screws may be
used to secure vent sections together if desired.
High temperature sealant is recommended at the appliance starter section
connection (use high-temperature silicone or Mill-Pac®).
If disassembly is required, at time of re-assembly check to see if the vent
creates a tight fit. If it does not, apply high temperature sealant to the joints
of the affected sections.
Horizontal sections require a 1/4" (6mm) rise every 12" (305mm) of travel
Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape)
© Travis Industries
(for qualified installers only)
6-5/8" (168mm) Diameter Vent
Reducer - # 98900165
1/8/2020 - 1505
23