ABL/ABLH9000 Series Stage User's Manual
Chapter 3: Operating Specifications
This chapter contains general technical information about ABL/ABLH9000 series stages. Included are basic
product specifications and general information on limit switches and motor wiring.
3.1. Environmental Specifications
The environmental specifications for the ABL/ABLH9000 are listed in the following table.
Table 3-1:
Environmental Specifications
Operating: 16° to 25° C (61° to 77° F)
Ambient
Temperature
The optimal operating temperature is 20° C ±2° C (68° F ±4° F). If at any time the operating tem-
perature deviates from 20° C degradation in performance could occur. Contact Aerotech for
information regarding your specific application and environment.
Storage: 0° to 40° C (32° to 104° F) in original shipping packaging
Humidity
Operating: 40 percent to 60 percent RH
The optimal operating humidity is 50 percent RH.
Storage: 30 percent to 60 percent RH, non-condensing in original packaging
Altitude
Operating: 0 to 2,000 m (0 to 6,562 ft) above sea level
Contact Aerotech if your specific application involves use above 2,000 m or below sea level.
Vibration
Use the system in a low vibration environment. Excessive floor or acoustical vibration can affect
stage and system performance. Contact Aerotech for information regarding your specific appli-
cation.
Dust Expo-
The ABL/ABLH9000 stages are not suited for dusty or wet environments. This equates to an
sure
ingress protection rating of IP00.
Use
Indoor use only
Do not expose the stage to environments or conditions outside the specified range of oper-
ating environments. Operation in conditions other than those specified can cause damage to
the equipment.
www.aerotech.com
Chapter 3
Operating Specifications
11