Figure 2-10: Inserting the IDU COM Cable into the Sealing Cap
Connect the Ethernet cable to the IDU COM RJ-45 connector.
2
Put the sealing cap back in its place. Make sure that the small protrusion on
3
the side of the cap fits inside the hole on the connector's protective body.
Figure 2-11: Connecting the IDU COM connector and inserting the Sealing Cap
Use appropriate sealing material to protect the connection against moisture
4
and humidity. Use removable sealing material to enable future access to the
connector.
NOTE
Use high quality sealing material such as Scotch
ensure IP-67 compliant protection against dust and water.
Route the cable to the location selected for the indoor equipment.
5
Assemble a shielded RJ-45 connector with a protective cover on the indoor
6
end of the IDU-ODU cable. See Appendix D for instructions on preparing the
cable.
Installation
Installing the Outdoor Unit
®
130C Linerless Rubber Splicing Tape from 3M to
45