MIB Parameter
*AdbTxFailed ModLevel5
(*AUAdbEntry 21)
*AdbTxFailed ModLevel6
(*AUAdbEntry 22)
*AdbTxFailed ModLevel7
(*AUAdbEntry 23)
*AdbTxFailed ModLevel8
(*AUAdbEntry 24)
*AdbCirTx
(*AUAdbEntry 25)
*AdbMirTx
(*AUAdbEntry 26)
*AdbCirRx
(*AUAdbEntry 27)
*AdbMirRx
(*AUAdbEntry 28)
*AdbCirMaxDelay
(*AUAdbEntry 29)
*AdbDistance
(*AUAdbEntry 30)
*AdbHwRevision
(*AUAdbEntry 31)
*AdbCpldVer
(*AUAdbEntry 32)
*AdbCountryCode
(*AUAdbEntry 33)
*AdbBootVer
(*AUAdbEntry 34)
*AdbAtpcOption
(*AUAdbEntry 35)
BreezeACCESS VL System Manual
Description
Applicable to AU/BU. Read-only. Counts
the total number of failures to
successfully
transmit a unicast
frame intended to the SU during a HW
Retry cycle using modulation level 5.
Applicable to AU/BU. Read-only. Counts
the total number of failures to
successfully
transmit a unicast
frame intended to the SU during a HW
Retry cycle using modulation level 6.
Applicable to AU/BU. Read-only. Counts
the total number of failures to
successfully
transmit a unicast
frame intended to the SU during a HW
Retry cycle using modulation level 7.
Applicable to AU/BU. Not applicable to
units with HW revision A. Read-only.
Counts the total number of failures to
successfully transmit a unicast frame
intended to the SU during a HW Retry
cycle using modulation level 8.
Applicable to AU Only. Not applicable to
BreezeNET B products. Read-only. The
value configured in the relevant SU for
the CIR: Uplink parameter.
Applicable to AU/BU. Read-only. The
value configured in the relevant SU for
the MIR: Uplink parameter.
Applicable to AU. Not applicable to
BreezeNET B products. Read-only. The
value configured in the relevant SU for
the CIR: Downlink parameter.
Applicable to AU/BU. Read-only. The
value configured in the relevant SU for
the MIR: Downlink parameter.
Applicable to AU. Not applicable to
BreezeNET B products. Read-only. The
value configured in the relevant SU for
the Maximum Delay parameter.
Applicable to AU/BU. Read-only. The
measured distance between the
relevant SU/RB and the AU/BU (In
Kilometers).
Applicable to AU/BU. Read-only. The
HW Revision of the relevant SU/RB.
Applicable to AU/BU. Read-only. The
CPLD Version of the relevant SU/RB.
Applicable to AU/BU. Read-only. The
Country Code of the relevant SU/RB.
Applicable to AU/BU. Read-only. The
Boot Version of the relevant SU/RB.
Applicable to AU/BU. Read-only. The
current ATPC Option of the relevant
SU/RB.
breezeAccessVLMib
Value/Range
Counter 32
Counter 32
Counter 32
Counter 32
Integer
Integer
Integer
Integer
Integer
Integer
1 means any distance
below 2 km
Integer
hwRevisionA (1),
hwRevisionB (2),
hwRevisionC (3),
hwRevisionD (4),
hwRevisionE (5),
na(255)
DisplayString
Integer
DisplayString
Integer
disable (1),
enable (2),
na(255)
257