Ethernet Link; Table 4-4: Ethernet Link Diagnostics - Alvarion BreezeACCESS LB System Manual

Alvarion breezeaccess breezeaccess lb wireless bridge: user guide
Hide thumbs Also See for BreezeACCESS LB:
Table of Contents

Advertisement

Chapter 4 - Diagnostics and Troubleshooting

Ethernet Link

The Link LED flashes when the LAN connection to the host
computer/server or switch/router is functioning properly and there is
traffic. If the LED is off, look for the following problems:
Symptom
No Ethernet Link
(Link LED off)
4-6
The Ethernet Link LED will light solid
green when the LAN connection to the host
computer/server or switch/router is
functioning properly.

Table 4-4: Ethernet Link Diagnostics

Possible Problem
Poor cable connection between
LB NI-01 Indoor unit and
computer/server or between LB
NI-01 Indoor unit and
switch/router.
Wrong type of Ethernet cable
between LB NI-01 Indoor unit
LAN port and host
computer/server or
switch/router.
The auxiliary Network
equipment including
switch/router, host
computer/server, may be
malfunctioning.
Processor malfunction.
Solution
Carefully check all
cable connections.
If the LB NI-01 Indoor
unit LAN port is
connected to a host
computer or server
directly, then ensure
a straight-through
cable is used.
Otherwise, to connect
the LB NI-01 Indoor
unit to a switch or
router, ensure a
crossover cable is
used.
Repair or replace
faulty units.
Try short reset or
long reset.