Chapter 3 - Commissioning
Table 3-5: Log Messages and Descriptions
Log Message
217- PLL unlocked!
218-Outdoor unit over
temperature!
219-Excessive DC loss on IF
cable!
220-Outdoor unit power supply
fault!
221-\public\ community can't
be deleted!
222-Max.community number
already defined!
223-Community name already
defined!
224-MIB initialization error!
225-Error while loading SNMP
configuration!
3-28
Description
One or more RF synthesizers unlocked. The
unit stopped RF transmissions and attempted
to reprogram the synthesizers. If this message
repeats or if the RF link is not back on, try to
reset the indoor unit. If the problem persists,
contact customer support.
The LB RE-01 ODU internal temperature rose
above 185F / 85C. The transceiver will shut
down for 30 seconds to allow cooling.
The DC voltage at the transceiver (carried by
the IF cable from the LB NI-01 indoor unit) is
lower than the required 24VDC. Check the IF
cable and connectors.
Indicates a fault in the transceiver's power
supply. This error could be due to a problem
with the internal power supply, or with the
power source from the LB NI-01 indoor unit. If
the 'Excessive DC loss on IF cable' error is
also indicated, check the IF cable and
connectors. If not, the LB RE-01 ODU will
require servicing.
The default 'Public' SNMP community cannot
be deleted.
No more communities may be defined, as the
maximum number has been reached
The name for the SNMP community has
already been used. Choose another name.
MIB construction process generated an error.
Try to reset the indoor unit. If problem
persists, contact customer support.
EEPROM memory was corrupted and the
SNMP configuration couldn't be loaded.
Default SNMP configuration was loaded.