Alvarion BreezeACCESS LB System Manual page 58

Alvarion breezeaccess breezeaccess lb wireless bridge: user guide
Hide thumbs Also See for BreezeACCESS LB:
Table of Contents

Advertisement

Chapter 3 - Commissioning
Master Mode: Sets one of the BreezeACCESS LB units to serve as the
master system, while the other BreezeACCESS LB unit assumes a slave
role. There are no consequences related to setting either unit to serve as
the master or slave for this version release.
Software Version: Specifies the current version of the system software.
Note that the software can be remotely downloaded into the
BreezeACCESS LB unit. The system includes sufficient memory to hold
two independent software loads. The operator can specify which
software load is used in the system.
Encryption Enable: Specifies whether the over-the-air encryption is
enabled. Note if encryption is enabled, it must be enabled on both the
local and remote units. Otherwise, no Ethernet traffic can be
transferred.
Encryption Key: Enter the MAC address of the remote LB NI-01
Indoor unit to enable over-the-air data encryption. Note, if the MAC
address is not properly entered, no Ethernet packets can be transferred.
Manual Link Length Mode: Specifies whether the link length is
calculated automatically or the link is manually specified. Default is
auto.
Link Measurements Units: Specifies the current units used for
entering the link length. Default is miles.
Link Length: Actual length of the path that the wave travels in order to
establish a link.
General Antenna Alignment (Buzzer): Enables the antenna alignment
tone sweep generator located in the LB RE-01 Outdoor unit for fine
tuning using actual signal strength. Faster repetitions of the tone
sweep indicate better alignment.
Radio Enable: Specifies whether radio transmission is enabled.
Save: Saves the currently entered parameters. Note that clicking Save
Configuration will also initiate a "short reset" - a useful feature when a
reset is required on a remote LB NI-01 Indoor unit.
Test: Allows testing of the current settings for five minutes, after which
the system reverts to the previously saved settings. To make settings
permanent, click on "Save".
System Reset: Resets all statistics and reboots the indoor unit.