Appendix A - Bluetooth LE Controller Properties (Bluetooth LE Only)
A.8
Bluetooth LE Property 0x0C - Desired Minimum Connection Interval
Bluetooth LE Property ID: 0x0C
Get Property: Yes
Set Property: Yes
Non-Volatile: Yes
Default value: 10 (12.5 milliseconds)
This property is a two byte integer in least significant byte order, in 1.25 millisecond increments, that
contains the Interval Min value the device sends to the Bluetooth LE host in a CONNECTION
PARAMETER UPDATE REQUEST (see the core Bluetooth specification for details). Only values
between 6 and 3200 are valid.
This property is stored in non-volatile memory, so it persists when the device is power cycled. This
property would typically only be changed once during device configuration if needed. Modifying this
property too many times wears out flash memory.
When this property is changed, the device must be reset (see Command 0x02 - Reset Device) or powered
off for at least 30 seconds, then powered on, before the changes will take effect.
Example Set Request (Hex)
Cmd Num
Data Len
46
06
Example Set Response (Hex)
Result Code
00
eDynamo| Secure Card Reader Authenticator | Programmer's Manual (COMMANDS)
01 00 01 0C 0A 00 (12.5 milliseconds)
Data Len
03
Page 167 of 245 (D998200115-17)
Data
Data
01 01 00
Need help?
Do you have a question about the eDynamo and is the answer not in the manual?
Questions and answers