Monitoring And Display Of Process Values; Sound Pressure Level - GEA RedGenium Operating Instruction

Table of Contents

Advertisement

Technical data

Monitoring and display of process values

5.6
Monitoring and display of process values
The following operating parameters are continuously monitored and displayed by the control:
Designation
Suction pressure
Discharge pressure
Oil pressure
Crankcase pressure
Suction temperature
Discharge temperature
Oil temperature
External temperature
SR inlet temperature
Motor current
Motor speed
Heating agent inlet temperature
Heat carrier outlet temperature
Heat carrier inlet temperature into
desuperheater / condenser
Heat carrier outlet temperature of
subcooler
Operating hours
Auto start delay
GEA VTrac™
Oil return temperature
Switch-on blocking time
Compulsory break
Ambient air temperature
5.7

Sound pressure level

Measuring-surface sound pressure level
Distance to the machine surface: 1 m (A-sound level at free field conditions on
reflecting surface) for heat pumps (1 compressor and 1 drive motor).
Determining the measurement values without secondary sound insulation.
64
Remark
Suction pressure in bar (a) and the corresponding evaporating temperature in °C
Discharge pressure in bar (a) and the corresponding condensation temperature in °C
Oil pressure in bar(a)
Crankcase pressure in bar (a)
Suction temperature in °C
Discharge temperature in °C
Oil temperature in °C
Secondary refrigerant - outlet temperature in °C
Secondary refrigerant - inlet temperature in °C
Motor current in A
Motor speed in rpm
Heat carrier inlet temperature into the heating circuit in °C
Heat carrier outlet temperature from the heating circuit in °C
Intermediate temperature from the heat carrier circuit between condenser and desuperheater in
°C
Intermediate temperature from the heat carrier circuit after subcooler exit in °C
Running hours
Remaining time for auto start delay in sec.
Continuous monitoring of the compressor and motor bearings by means of two sensors in m/s
for early detection of sudden bearing damage
(no normal long-term wear)
Temperature in oil collection tank in °C
Start to start, remaining time between two starts of the compressor in sec.
Compulsory break timer, remaining time in sec.
External temperature in °C
Notice
Measuring-surface sound-pressure level strongly depends on the type of
the heat pump and especially on the type of the drive motor (manufacturer,
type, protection type).
► We can provide you with the values on request. Contact the Design or
Sales department at GEA Refrigeration Germany GmbH.
L_151511_2
19.12.2019