Warning Against Foreseeable Abusive Use - GEA RedGenium Operating Instruction

Table of Contents

Advertisement

Safety

Warning against foreseeable abusive use

ler or the operator, not the manufacturer, is responsible for all injury to personnel
and damage to property which results from non-authorised use.
The pressure equipment is not designed for dynamic loads. If there is a risk of
lightning strikes, the pressure equipment must be earthed. The supplier/installer
must include instructions for regular inspection of the pressure equipment in his
operating instructions and must specify the procedure to be followed by the end
user in the event of damage. In order to prevent burns or frostbite, the pressure
equipment must not be touched during operation. This can be prevented by
appropriate safety measures. The appropriate warning signs must be affixed.
Refrigerating systems/heat pumps must be equipped with safety valves accord-
ing to EN 378. The supporting surface must provide sufficient rigidity.
The supplier/installer must exercise due care when installing the accessories for
the pressure equipment. The pressure equipment must not be damaged during
installation and must be painted after installation. The pressure equipment must
be filled only with the refrigerant specified in the contract. The pressure equip-
ment must be installed in the system in such a way that no vibration or pulse is
transferred to the pressure equipment. The connection lines must be installed
only when de-energised.
Intended use includes observance of this manual and all supplied operating man-
uals as well as compliance with the maintenance and service intervals and condi-
tions stipulated therein.
Improper use of the equipment shall void any warranty entitlement and approval
for operation.
2.2
Warning against foreseeable abusive use
A product is said to have been abused if:
20
Notice
Unauthorised refrigerants, fuels as well as secondary refrigerants and cool-
ing media are used.
► Observe the specifications for the project!
Notice
electrical components are wrongly connected.
► Observe voltage and frequency!
Notice
mechanical components are wrongly connected.
► Observe pressure and temperature!
The supporting, hanging and storage facilities are misused,
Control and regulation units including control software are tampered with,
The driving power generated by the motor is used for purposes other than the
operation of the respective compressors and pumps.
L_151511_2
19.12.2019

Advertisement

Table of Contents
loading