3.1.5

Information and safety labels on the product

3.1.5.1 Labels of the pressure and temperature sensors, heater

(safety labels)
Fig.13:
Importance of the labels:
Before replacing pressure and temperature sensors without dip tube, it must be
ensured that the pipes into which the sensors are mounted are not pressurised.
The pressure-free state can be achieved by closing the shut-off valves before the
sensor to be replaced.
Before replacing oil heater, it must be ensured that the compressor into which the
oil heater is screwed in is not pressurised.

3.1.5.2 Marking the safety valves

(safety labels)
Fig.14:
Importance of the labels:
The safety valve must be connected to a blow-off line that leads to the outside.

3.1.5.3 Labels of the screwed connections with cutting ring

(handling instructions)
L_151511_2
19.12.2019
Danger
Danger to life by failure to observe and follow the labels on the product!
► Be sure to observe and follow the safety-relevant labels on the product!
Safety labels of the pressure and temperature sensors, heater
Marking the safety valves