GEA SHA series Assembly Instructions Manual
GEA SHA series Assembly Instructions Manual

GEA SHA series Assembly Instructions Manual

Bock condensing units

Advertisement

GEA Bock Condensing Units
Assembly instructions
09600-08.2017-Gb
Translation of the original instructions
SHA(X)12P...L
SHG(X)12P...L
SHA(X)22e...L
SHG(X)22e...L
SHA(X)34e...L
SHG(X)34e...L
SHA(X)4...L
SHG(X)44e...L
SHG(X)5...L
SHG(X)56e...L
SHG(X)6...L
SHGZ(X)7...L
D
GB
F
E
1

Advertisement

Table of Contents
loading

Summary of Contents for GEA SHA series

  • Page 1 GEA Bock Condensing Units Assembly instructions 09600-08.2017-Gb Translation of the original instructions SHA(X)12P...L SHG(X)12P...L SHG(X)5...L SHA(X)22e...L SHG(X)22e...L SHG(X)56e...L SHA(X)34e...L SHG(X)34e...L SHG(X)6...L SHA(X)4...L SHG(X)44e...L SHGZ(X)7...L...
  • Page 2 These instructions must be passed onto the end customer along with the unit in which the condens- ing unit is installed. Observe also the other documentation included with the condensing unit. Manufacturer GEA Bock GmbH 72636 Frickenhausen Contact GEA Bock GmbH Benzstraße 7...
  • Page 3: Table Of Contents

    2016 July 1st in the EU only products may be sold which fulfill minimum efficiency requirements. These minimum efficiency requirements must be documen- ted by a certificate. The matching certificate for your condensing unit can be created on the Internet on our software (VAP) under http://vap.gea.com/stationaryapplication/...
  • Page 4: Safety

    1 | Safety 1.1 Identification of safety instructions: DANGER Indicates a dangerous situation which, if not avoided, will cause immediate fatal or serious injury. WARNING Indicates a dangerous situation which, if not avoided, may cause fatal or serious injury. CAUTION Indicates a dangerous situation which, if not avoided, may cause fairly severe or minor injury. ATTENTION Indicates a situation which, if not avoided, may cause property damage. INFO Important information or tips on simplifying work. 1.2 Qualifications required of personnel WARNING Inadequately qualified personnel poses the risk of accidents, the consequence being serious or fatal injury. Work on compressors is therefore reserved for personnel which is qualified to work on pressurized refrigerant systems: • For example, a refrigeration technician, refrigeration mechatronic engineer. As well as professions with comparable training, which enables personnel to assemble, install, maintain and repair refrigeration and air-conditioning systems.
  • Page 5: Safety Instructions

    These assembly instructions describe the standard version of the condensing units named in the title manufactured by GEA. The condensing unit is intended for installation in a machine (within the EU according to the EU Directives 2006/42/EC Machinery Directive, 2014/68/EU Pressure Equipment Directive).
  • Page 6: Product Description

    2 | Product description 2.1 Short description Condensing unit with vertical receiver Condenser Receiver Compressor Condensing unit with horizontal receiver Condenser Compressor Receiver Dimension and connection values can be found in Chapter 7...
  • Page 7: Name Plate

    2 | Product description 2.2 Name plate (example) GEA Bock GmbH 72636 Frickenhausen, Germany SHGX34e/315-4 L AX38125A001 19/28 Type designation Machine number ND (LP): Max. admissible operating pressure suction side HD (HP): Max. admissible operating pressure high-pressure side 2.3 Type key (example)
  • Page 8: Areas Of Application

    3 | Areas of application 3.1 Areas of application • The operating limits of the condensing units differ to the respective compressor. The really operating limits can be found on the Internet on our software (VAP) under vap.gea.com. 4 | Assembly INFO New compressors are factory-filled with inert gas (3 bar nitrogen).
  • Page 9: Maintenance

    4 | Assembly Set up on an even surface or frame with sufficient load-bearing capacity. Only set up on a slant after following consulting. Preferably on vibration damper or mounting rubbers. Sun protection: If the condensing unit is set up outdoors, it has to be protected from direct sunlight.
  • Page 10: Technical Data

    6 | Technical Data Fan / Condenser (230 V - 1- 50 Hz) Receiver Weight capacity Max. Max. Air flow working current power consumption 50 Hz 50 Hz 50 Hz m³/h Ltr. Type SHG12P/60-4 SL 1,22 3550 SHG12P/75-4 L 1,22 3550 SHG12P/75-4 SL 1,22 3550 SHG12P/90-4 L 1,22 3550 SHG12P/90-4 SL 1,22 3550 SHG12P/110-4 L...
  • Page 11 6 | Technical Data Fan / Condenser (230 V - 1- 50 Hz) Receiver Weight capacity Max. Max. Air flow working current power consumption 50 Hz 50 Hz 50 Hz m³/h Ltr. Type SHG44e/475-4 L 2 x 2,50 2 x 500 9490 14,0 SHG44e/475-4 SL 4 x 2,50 4 x 500 16280 14,0 SHG44e/565-4 L...
  • Page 12 6 | Technical Data Fan / Condenser (230 V - 1- 50 Hz) Receiver Weight capacity Max. Max. Air flow working current power consumption 50 Hz 50 Hz 50 Hz m³/h Ltr. Type SHA12P/60-4 L 1,22 3550 SHA12P/75-4 L 1,22 3550 SHA12P/90-4 L 1,22 3550 SHA12P/110-4 L 1,22 3550 SHA22e/125-4 L 1,22 3550 SHA22e/160-4 L...
  • Page 13: Dimensions And Connections

    / Verified prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event GEA Bock GmbH - Benzstraße 7 - 72636 Frickenhausen - Germany - www.bock.de Freigabe / Approved Zust. / Rev. Änd.-Nr. / Mod-No.
  • Page 14 7 | Dimensions Dimensions Type SHG22e/125-4 L SHG22e/125-4 SL SHG22e/160-4 L SHG22e/160-4 SL SHG22e/190-4 L 1085 1060 SHG22e/190-4 SL 1085 1060 SHG34e/215-4 L 1085 1060 SHG34e/215-4 SL 1085 1060 SHG34e/255-4 L 1085 1060 SHG34e/255-4 SL 1085 1060 SHG34e/315-4 L 1085 1060 SHG34e/315-4 SL 1220...
  • Page 15 7 | Dimensions SHG / SHGZ / SHA Dimensions Type SHG6/1240-4 SL 1300 1140 1610 SHG6/1410-4 L 1300 1140 1610 SHG6/1410-4 SL 1300 1140 1610 SHGZ7/1620-4 L 1300 1140 1610 1090 SHGZ7/1860-4 L 1300 1140 1610 1090 SHGZ7/2110-4 L 1300 1140 1610 1090...
  • Page 16 7 | Connections Connections 1 Type mm I Inch mm I Inch Inch Inch Inch SHG12P/60-4 SL 16 / 12 / SHG12P/75-4 L 16 / 12 / SHG12P/75-4 SL 16 / 12 / SHG12P/90-4 L 16 / 12 / SHG12P/90-4 SL 16 / 12 / SHG12P/110-4 L...
  • Page 17 7 | Connections Connections 1 SHGZ mm I Inch mm I Inch Inch Inch Inch Type SHG56e/995-4 L 54 / 2 22 / NPTF SHG56e/995-4 SL 54 / 2 22 / NPTF SHG56e/1155-4 L 54 / 2 22 / NPTF SHG56e/1155-4 SL 54 / 2 22 /...
  • Page 18 If you have any questions about installation, operation and accessories, please contact our technical service or specialist wholesaler and/or our representative. The GEA service team can be contacted by phone with a toll-free hotline 00 800 / 800 000 88 or via e-mail: info@gea.com...
  • Page 20 • • GEA Group is a global engineering company with multi-billion euro sales and operations in more than 50 countries. Founded in 1881, the company is one of the largest providers of innovative equipment and process technology. GEA Group is listed in the STOXX ®...