Repair And Extraordinary Maintenance; Maintenance Intervals - Electrolux Combi TOUCH User Manual

Electrical and gas oven
Table of Contents

Advertisement

Replacing door seal
The door seal is a component that can become worn over
time. It is advisable to replace it whenever any hardening or
breakage is noticed.
To replace it, proceed as follows:
1. Remove the seal from its seat;
2. Clean the latter of any traces of dirt;
3. Insert the new seal along the entire seat.
1
2
F.3

Maintenance intervals

All the components requiring maintenance are accessible from the front or the rear panel of the appliance.
The inspection and maintenance intervals depend on the actual machine operation conditions and ambient conditions (presence of
dust, damp, etc.), therefore precise time intervals cannot be given.
In any case, careful and periodical machine maintenance is advisable in order to minimise service interruptions.
To ensure constant machine efficiency, it is advisable to carry out the checks with the frequency given in the following table:
IMPORTANT
Machine maintenance, checking and overhaul operations must only be carried out by a specialised Technician or the
Customer Care Service, provided with adequate personal protection equipment (safety shoes and gloves), tools and
ancillary means;
Work on the electrical equipment must only be carried out by a specialised electrician or the Customer Care Service.
Maintenance, inspections, checks and cleaning
Ordinary cleaning
• general cleaning of machine and surrounding area.
Mechanical protection devices
• check their condition and for any deformation, loosening or
removed parts.
Control
• check the mechanical part, for cracks or deformation, tighten-
ing of screws: check the readability and condition of words,
stickers and symbols and restore if necessary.
Machine structure
• tightening of main bolts (screws, fixing systems, etc.) of
machine.
Safety signs
• check the readability and condition of safety signs.
Electrical control panel
• check the electrical components installed inside the electrical
control panel. Check the wiring between the electrical panel
and machine parts.
Electrical connection cable and plug
• check the connection cable (replace if necessary) and plug.
Preventive maintenance
• check all gas components (if present).
Preventive maintenance
• remove any deposits of dirt inside the appliance.
Control
• check the conditions of the internal parts.
52
F.2

Repair and extraordinary maintenance

NOTE!
Repair and extraordinary maintenance have to be
carried out by specialised authorised personnel,
who can ask the manufacturer to supply a servicing
manual.
Frequency
Daily
Yearly
Yearly
Yearly
Yearly
Yearly
Yearly
Yearly
1
Every 6 months
1
Every 6 months
Responsibility
Operator
Service
Service
Service
Service
Service
Service
Service
Service
Service