13.1

Signal indicators of the integrated control unit PICO-troniX1

The functions of the device are displayed via two LEDs (green and red) in the inspection window of the protective housing
(see fig. 36), whereby the red LED always displays an error in the program sequence.
The functions of the device can also be displayed by externally installed signal lamps. However, these have to be ordered
separately (order number on request).
If several errors occur at the same time, they are displayed one after the other with a break of approx. 2 seconds.
Signal indicators
ON
LED red
OFF
ON
LED green
OFF
ON
LED red
OFF
ON
LED green
OFF
ON
LED red
OFF
ON
LED green
OFF
ON
LED red
OFF
ON
LED green
OFF
ON
LED red
OFF
ON
LED green
OFF
ON
LED red
OFF
ON
LED green
OFF
© BEKA 201 All
9
rights reserved
...a product of
Operable: 1.5 s
During the whole lubrication
1 s
1 s 1 s 1 s
1 s 1 s
Until lubricant is refilled
1 s 1 s
!
Function
Indication of the operational
capability after switching on the
voltage for the first time
Sequence of a lubrication
Error Lubrication deficit
Revolution error in operational mode
of revolution-dependent lubrication
duration
Error Level too low
(only for devices with follow-up
piston)
Trial lubrication (permanent
lubrication) In order to initiate a
permanent lubrication for service
purposes in the operational mode of
time-dependent lubrication duration,
the lubrication duration has to be set
higher than the cycle duration.
54
;