Installation and Configuration
EXMs must be defined in this screen so the BIOS can correctly identify and initialize
each one at boot-up. Each EXM must be listed by slot number, ID and two option
bytes as defined below.
SLOT
indicates the EXM card edge connector in which the EXM is
installed. Refer to Figure 5 below to determine which slot the EXM
occupies. Dashed lines indicate that not all slots are available in
some configurations.
ID
is a hard-wired identification value. Each type of EXM has a
unique ID value.
OB1/OB2
are two "option" bytes of configuration information.
EXM Slots
0
1
2
3
4
Figure 5. EXM Slot Numbering.
All slots not occupied by an EXM module show an ID of FF, indicating that no EXM
is present. Note that the EPC-23 can be installed in any slot, and does not require any
ID or option byte information.
Consult the EXM manual for the correct configuration information for each EXM
expansion module installed.
After all EXMs have been configured, press F10 to save the data or ESC to ignore the
changes. In either case you return to the main setup screen.