Application Constants: B - YASKAWA Varispeed E7 Instruction Manual And Parameter Description

Hvac frequency inverter
Hide thumbs Also See for Varispeed E7:
Table of Contents

Advertisement

Application Constants: b

Operation Mode Selections: b1
Con-
stant
Number
Reference source
b1-01
selection
RUN command
b1-02
source selection
Stopping method
b1-03
selection
Prohibition of
b1-04
reverse operation
Operation selec-
tion after switch-
b1-07
ing to remote
mode
Run command
b1-08
selection in pro-
gramming modes
b1-11 RUN delay
-12
5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Name
Description
Sets the frequency reference input
method.
0: Digital Operator
1: Control circuit terminal (analog
input)
2: MEMOBUS communications
3: Option Card
Sets the run command input
method.
0: Digital Operator
1: Control circuit terminal (digital
multifunktion inputs)
2: MEMOBUS communications
3: Option Card
Used to set the stopping method
used when a stop command is input.
0: Deceleration to stop
1: Coast to stop
2: DC injection braking stop (Stops
faster than coast to stop, no
regenerative operation.)
3: Coast to stop with timer (Run
commands are disregarded
during deceleration.)
0: Reverse enabled
1: Reverse disabled
2: Output Phase Rotation (both
rotational directions are enab-
led)
3: Output Phase Rotation with
Reverse prohibited.
Used to set the operation mode by
switching to the Remote mode
using the Local/Remote Key.
0: Run signals that are input during
mode switching are disregarded.
(Input Run signals after
switching the mode.)
1: Run signals become effective
immediately after switching to
the Remote mode.
Used to set an operation interlock in
programming modes.
0: Cannot operate.
1: Can operate (Disabled when
Digital Operator is set to select
run command (when b1-02 =
0)).
Sets the delay time for the internal
RUN command.
Change
Access
during
Setting
Factory
Range
Setting
Level
Opera-
tion
0 to 3
1
No
Q
0 to 3
1
No
Q
0 to 3
0
No
Q
0 to 3
0
No
A
0 or 1
0
No
A
0 or 1
0
No
A
0 to
0 s
No
A
600s
MEMO-
BUS
Page
Register
6-5
180H
6-51
6-9
181H
6-51
182H
6-11
183H
6-37
186H
187H
1DFH

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Cimr-e7c

Table of Contents