Energy Monitor Initialize (o2-14)
This function can be used to initialize the energy monitor by setting parameter o2-14 to 1.
HAND Key Funktion Selection (o2-15)
With this parameter the HAND key can be disabled by setting parameter o2-15 to 0. The factory setting is 1,
HAND key enabled.
Copying Constants
The Digital Operator can perform the following three functions using a built-in EEPROM (non-volatile mem-
ory).
Store Inverter constant set values in the Digital Operator (READ)
•
Write constant set values stored in the Digital Operator to the Inverter (COPY)
•
Compare constant set values stored in the Digital Operator with Inverter constants settings (VERIFY)
•
Related Constants
Con-
stant
Name
Number
o3-01
Copy function selection
o3-02
Read permitted selection
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Description
0: Normal operation
1: READ (Inverter to Operator)
2: COPY (Operator to Inverter)
3: Verify (compare)
0: READ prohibited
1: READ permitted
Digital Operator Functions
Change
Setting
Factory
during
Access
Range
Setting
Opera-
Level
tion
0 to 3
0
No
A
0 or 1
0
No
A
105
6-