Output Terminal Functions

The digital multifunction outputs can be set for several functions using the H2-01 and H2-02 constants (termi-
nal M1 to M4 function selection). These functions are described in the following section.
Related Constants
Con-
stant
Name
Number
Terminal M1-M2 function selec-
H2-01
tion
Terminal M3-M4 function selec-
H2-02
tion
During Run (Setting: 0) and During Run 2 (Setting: 37)
During Run (Setting: 0)
OFF The Run command is OFF and there is not output voltage.
ON
The Run command is ON or a voltage is being output.
During Run 2 (Setting: 37)
OFF The inverter is not outputting a frequency. (Baseblock, DC injection braking or stopped)
ON
The inverter is outputting a frequency.
These outputs can be used to indicate the inverter's operating status.
Run command
OFF
OFF
Baseblock command
Output frequency
During run 1 output
OFF
During run 2 output
OFF
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Description
Multi-function contact output 1
Multi-function contact output 2
ON
ON
ON
ON
Fig. 6.40 Timing Chart for "During RUN" Output

Output Terminal Functions

Change
Setting
Factory
Access
during
Range
Setting
Level
Operation
0 to 38
0
No
0 to 38
1
No
A
A
63