Con-
Name
stant
Number
Sets the brightness on the optional LCD
operator (JVOP-160).
0: light
1:
o1-05 LCD-Focus
2:
3: normal
4:
5: dark
Selects the monitor that is displayed and
2nd Monitor
o1-07
locked in the second line of the operator
*6
Selection
display
Selects the monitor that is displayed and
3rd Monitor
o1-08
locked in the third line of the operator dis-
*6
Selection
play
Clears or stores user initial values.
0: Stores/not set
1: Begins storing (Records the set
User constant
o2-03
2: All clear (Clears all recorded user
initial value
When the set constants are recorded as
user initial values, 1110 will be set in
A1-03.
When the frequency reference is set on
the Digital Operator frequency reference
monitor, sets whether the Enter key is
Frequency refer-
necessary or not.
o2-05
ence setting
0: Enter key needed
method selection
1: Enter key not needed
When set to 1, the Inverter accepts the fre-
quency reference without Enter key oper-
ation.
0: Cumulative time when the Inverter
Cumulative
o2-08
operation time
selection
1: Cumulative Inverter run time. (Only
Read permis-
0: READ prohibited
o3-02
sion selection
1: READ permitted
* 1. The factory setting depends on the Inverter capacity.
* 2. These are values for a 200 V class Inverter. Values for a 400 V class Inverter are double.
* 3. After autotuning, E1-13 will contain the same value as E1-05.
* 4. The factory setting depends on the Inverter capacity. (The value for a 200 V Class Inverter for 0.4 kW is given.)
* 5. The setting range is from 10% to 200% of the Inverter rated output current. (The value for a 200 V Class Inverter for 0.4 kW is given.)
* 6. Parameter is only effective if HOA operator with LCD (JVOP-162) is used.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Description
constants as user initial values.)
initial values)
power is on. (All time while the
Inverter power is on is accumulated.)
Inverter output time is accumulated.)
Digital Operation Display Functions and Levels
Change
Access
during
Setting
Factory
Range
Setting
Opera-
tion
0 to 5
3
Yes
1 to 53
2
No
1 to 53
3
No
0 to 2
0
No
0 or 1
0
No
0 or 1
0
No
0 or 1
0
No
MEMO-
BUS
Level
Regis-
ter
A
509H
A
518H
A
519H
A
507H
A
509H
A
50CH
A
516H
9
5-