Common Alarm Relay
On the low voltage side of the terminal block there is a common alarm relay connection.
This can be used to connect to a home security system to send a signal that the generator has failed
and needs service.
When the controller is powered up and there are No Alarms, the relay contacts will be OPEN.
Any Alarm (Not warning) will trigger the common alarm relay to close the contacts.
The connections are made at Common Alarm 1 (209) and common alarm 2 (210).
Two – Wire Start
If using a two-wire start switch, after setting the generator to two-wire start yes in the dealer menu
on the Evolution control panel.
You will need optional wiring harness P/N 0J0973A and a special code to access the dealer menu.
When this switch closes the generator should start.
N1 and N2 are not used, as sensing will be done in the 2-wire switch.
T1 will still need 120VAC for the battery charger.
2-Wire Start may Void the Warranty.
Call for help, we have several different Schematics for two wire start.