Initial Console Programming
HINT: If you enter the wrong value when entering your data press "ENTER" then press "ENTER" again and re-enter your value again.
Select the unit of measurement by pressing the CE button until the desired selection appears in the display and press "ENTER"
NOTE - The unit of measurement for the United States is Volume per Acre.
Select the type of sensor by pressing the CE button until the desired sensor type appears in the display and press "ENTER".
For Phoenix 10, select SP2.
For wheel drive sensor, select SP1.
The message "CAL C-SD STANDARD VALVE" will appear in the console's display.
For PWM pump, press CE until C-PC (PWM Close Valve) appears. If tank agitation is desired, select C-P (PWM Open Valve) to
perform agitation. Make sure the agitation valve is partially open. Press "ENTER".
The message "CAL SELF TEST 00" will appear in the console's display. Press the "BOOM CAL 1" button and enter the value shown in the
table below. To store the values, press "ENTER" (the enter button will light up), input the value and then press "ENTER" to store your
value. Repeat for Boom 2 through 3. Press the arrow keys to advance to the remaining booms.
Boom #
12 Row
Boom 1
105
Boom 2
150
Boom 3
105
Press the "SPEED CAL" button and input the appropriate speed calibration value for the type of sensor being used and press "ENTER".
For Phoenix 10, the speed calibration is 785.
For wheel drive sensor, refer to the speed calibration steps in the Raven SCS 450 operator's manual.
Press the "METER CAL" button and enter the meter calibration value stamped on the flow meter's identification tag.
The meter calibration value is approximately 720 or 1340 check sticker next to flow meter for accurate number.
Press the "VALVE CAL" button and input the calibration number that corresponds with the control valve being used and press "ENTER".
For PWM Pump, the valve calibration is 0043 or 43.
Press the "RATE 1 CAL" button and "ENTER" the Rate 1 value. Refer to the "Calculate the Rate 1 and Rate 2 Cal Values" section of the
Raven SCS 450 manual and press "ENTER".
Press the "RATE 2 CAL" button and "ENTER" the Rate 2 value. Refer to the "Calculate the Rate 1 and Rate 2 Cal Values" section of the
Raven SCS 450 manual and press "ENTER".
The initial console programming is now complete, and the flashing "CAL" in the console's display should turn off. If it does not, repeat
the procedure starting from the first step above.
These settings will be stored and the previous steps do not need to be repeated after powering off or on.
RESET: If an entry or selection error is made during any steps of this procedure, turn the POWER switch to the OFF position, press and
hold CE while turning the POWER switch to the ON position to reset the console.
Setting Reaction Time for PWM Pump
To adjust rate reaction time in a PWM pump, navigate to "Data Menu" and set high PWM to 253 and low PWM to 1.
To adjust high PWM setting, adjust rate #1 to 50 GPA and rate #2 to 30 GPA. Run a self-test with hydraulics pumping out fluid at 8
mph. To perform self-test, set 8.0 as speed using the "ENTER" button and turn on the master while stationary. Start on rate #1. Once
the rate reaches 50 GPA, switch to rate #2. If it takes longer than desired to adjust to 30 GPA, adjust high PWM from 253 to 225 and
try again. Continue lowering by 25 and repeat until the rate adjusts as desired. (If needed, fine tuning by less than 25 is allowed).
To adjust low PWM setting, adjust rate #1 to 50 GPA and rate #2 to 30 GPA. Run a self-test with hydraulics pumping out fluid at 8
MPH. To perform self-test, set 8.0 as speed using the "ENTER" button and turn on the master while stationary. Start on rate #2. Once
the rate reaches 30 GPA, switch to rate #1. If it takes longer than you desire to adjust to 50 GPA, adjust low PWM from 1 to 25 and try
again. Continue raising by 25 and repeat until the rate adjusts as desired. (If needed, fine tuning by less than 25 is allowed).
In "Data Menu", set PWM Frequency to 122 Hz.
32

Quick Start for Raven 450 Controller

16 Row
165
150
165
Boom 3
Boom 2
Boom 1