Quick Start - J&M NITRO-GRO 5010 Operator's Manual

Precision applicator
Hide thumbs Also See for NITRO-GRO 5010:
Table of Contents

Advertisement

Quick Start For The Raven 440 Controller With Phoenix 10 GPS
Initial Console Programming
HINT: If you enter the wrong value when entering your data press "ENTER" then press "ENTER" again and re-enter your value again.
Select the unit of measure by pressing the CE button until the desired until of measure appears in the display and press "ENTER"
NOTE - The unit of measure for the United States is Volume per Acre.
Select the type of sensor being used (SP2) by pressing the CE button until the desired sensor type appears in the display and
press "ENTER"
The message "CAL C-SD STANDARD VALVE" will appear in the console's display. Press "ENTER"
The message "CAL SELF TEST 00" will appear in the console's display. Press the BOOM CAL 1 button and enter the value shown
in the table. To store the values press "ENTER" (the enter button will light up) input the value and then press "ENTER". Your
value is now stored. Repeat for Boom 2 and 3. Use the arrow keys to advance to the remaining booms.
Boom #
12 Row
16 Row
Boom 1
105
165
Boom 2
150
150
Boom 3
105
165
Press the "SPEED CAL" button and input the appropriate speed cal. value for the type of sensor being used and press "ENTER"
NOTE - For the PHOENIX 10 the speed cal. is 785.
Press the "METER CAL" button and enter the meter cal. value stamped on the flow meter's identification tag.
NOTE - The meter cal. value is 720 gallons.
Press the "VALVE CAL" button and input the calibration number that corresponds with the control valve being used and press "ENTER".
NOTE - For this unit the valve cal. is 2123.
Press the "RATE 1 CAL" button and "ENTER" the Rate 1 value. Refer to the "Calculate the Rate 1 and Rate 2 Cal Values" section of
the Raven SCS 440 manual and press "ENTER".
Press the "RATE 2 CAL" button and "ENTER" the Rate 2 value. Refer to the "Calculate the Rate 1 and Rate 2 Cal Values" section of
the Raven SCS 440 manual and press "ENTER".
The initial console programming is now complete, and the flashing "CAL" in the console's display should turn off. If it does not,
repeat the procedure starting from the first step above.
These settings will be stored and the previous steps do not need to be repeated after powering OFF/ON.
RESET: If an entry or selection error is made during any steps of this procedure, turn the POWER switch to the OFF position, press
CE and hold while turning the POWER switch to the ON position to reset the console.
HINT: If you enter the wrong value when entering your data press "ENTER" then press "ENTER" again and re-enter your value again.
Boom 3
Boom 2
20
Boom 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nitro-gro 5016

Table of Contents