Coulter
The number of coulters is determined by the number of rows
(usually one less or one more). So the number of rows will be
even, and the number of coulters will be odd, since you are
placing the nitrogen between the rows. Example, a 16 row unit
will have either 15 or 17 coulters. A 16 row applicator with 15
coulters is considered a "one-down" unit. Similarly, a 16 row
applicator with 17 coulters is considered a "one-up" unit.
Hand Wash Tank
The 9 gallon hand wash tank makes cleaning hands after
chemical spills quick and easy.
11