Product Specifications - Goodwe HT Series User Manual

Photovoltaic grid-tie inverter
Hide thumbs Also See for HT Series:
Table of Contents

Advertisement

7 Technical Data
7.1 Product Specifications
Technical Data
GW100K-HT
DC input parameters
Maximum DC input power (kW)
150
Maximum DC input voltage (V)
1100
MPPT operating voltage range (V)
180~1000
Minimum start-up voltage (V)
200
Rated input voltage (V)
600
Maximum input current (A)
10*30
Maximum short-circuit current (A)
10*45
No. of MPP Trackers
10
No. of Input Strings per Tracker
2
AC output data
Rated output power (kW)
100
Maximum output power (kW)
110
110
Maximum apparent power (kVA)
Rated output voltage (V)
400, 3L/N/PE or 3L/PE
Output frequency (Hz)
50/60
Maximum output current (A)
167
Power factor
Output THDi (@rated output)
<3%
Efficiency
Maximum conversion efficiency
European efficiency
Protection
String current monitoring
Internal humidity detection
Residual current monitoring
Insulation resistance detection
Anti-islanding protection
Input reverse protection
DC surge protection
AC surge protection
Output overcurrent protection
Output short circuit protection
Output overvoltage protection
AFCI DC arc protection
PID recovery
AC terminal overtemperature protection
Emergency quick shutdown
General Data
Operating temperature (℃)
Relative humidity
Operating altitude (m)
Cooling method
Interface
Communication
Weight (kg)
93.5
Dimensions (width x height x thickness mm)
Degree of protection
Night loss (W)
Topology
Certification & Standards
Grid-tie standard
Safety standard
EMC standard
29
GW110K-HT
GW120K-HT
165
180
1100
1100
180~1000
180~1000
200
200
600
600
12*30
12*30
12*45
12*45
12
12
2
2
110
120
121
132
121
132
400, 3L/N/PE or 3L/PE
400, 3L/N/PE or 3L/PE
50/60
50/60
175.5
191.3
~1 (0.8 leading�0.8 lagging adjustable)
<3%
<3%
98.6%
98.3%
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Type II (Type I optional)
Type II (Type I optional)
Integrated
Integrated
Integrated
Optional
Optional
Optional
Optional
-30~60
0~100%
≤4000
Intelligent forced air cooling
LED (Standard), LCD (Optional), Bluetooth+APP
RS485 or PLC 2.0 or WiFi
98.5
98.5
1005*676*340
IP66
<2
Transformerless
Interpretation of overvoltage levels:
Overvoltage level I: Connect the product to a circuit with measures to limit instantaneous
overvoltage to a relatively low level.
Overvoltage level II: Energy-consuming equipment powered by fixed power distribution devices.
GW136K-HTH
205
1100
180~1000
Overvoltage level III: The reliability and applicability of equipment in fixed power distribution
200
750
12*30
12*45
12
2
Overvoltage level IV: The equipment used in the power supply of the power distribution device,
including measuring instruments and prepositioned overcurrent protection equipment, etc.
136
150
150
Interpretation of humid places
500, 3L/PE
50/60
Environmental
173.2
Parameters
<3%
Temperature range
99.0%
Humidity range
98.5%
Interpretation of environmental levels:
Outdoor inverter: The ambient air temperature range is -25°C~+60℃, suitable for pollution level 3
environment;
Indoor type II inverter: The ambient air temperature range is -25°C~+40℃, suitable for pollution
Indoor type I inverter: The ambient air temperature range is 0°C~+40℃, suitable for pollution
Interpretation of pollution levels
Pollution level 1: No pollution or only dry non-conductive pollution;
Pollution level 2: Usually there is only non-conductive pollution, but there may be temporary
Pollution level 3: There is conductive pollution, or non-conductive pollution becomes conductive
Pollution level 4: There is persistent conductive pollution, such as pollution caused by conduc-
98.5
Such equipment includes appliances, portable tools and other household and
similar loads. If there are special requirements for the reliability and applicability
of such equipment, overvoltage level III shall be adopted.
installations must meet special requirements, including switching appliances in
fixed power distribution devices and industrial equipment permanently connect-
ed to fixed power distribution devices.
3K3
0°C~+40℃
-33°C~+40℃
5% to 85%
15% to 100%
level 3 environment;
level 2 environment;
conductive pollution caused by condensation;
pollution due to condensation;
tive dust or rain and snow.
Level
4K2
4K4H
-20°C~+55℃
4% to 100%
30

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gw100k-htGw110k-htGw120k-htGw136k-hthGrid-tie ht seriesGrid-tie gw100k-ht ... Show all

Table of Contents