Goodwe HT Series User Manual

Goodwe HT Series User Manual

Photovoltaic grid-tie inverter
Hide thumbs Also See for HT Series:

Advertisement

SolarGo APP
SEMS Portal App
SEMS Portal website
GOODWE (Germany)
Fürstenrieder Str. 279a 81377 München, Germany
T: +49 8974120210 +49 421 83570-170 (service)
sales.de@goodwe.com
service.de@goodwe.com
GOODWE (Netherlands)
Franciscusdreef 42C, 3565AC Utrecht, the Netherlands
T: +31 (0) 30 737 1140
sales@goodwe.com
service.nl@goodwe.com
GOODWE (India)
1202, G-Square Business Park, Sector 30A, Opp. Sanpada
Railway Stn., Vashi, Navi Mumbai- 400703
T: +91 (0) 2249746788
sales@goodwe.com / service.in@goodwe.com
GOODWE (Turkey)
Adalet Mah. Megapol Tower K: 9 No: 110 Bayraklı - Izmir
T: +90 (232) 935 68 18
info@goodwe.com.tr
service@goodwe.com.tr
GOODWE (Mexico)
Oswaldo Sanchez Norte 3615, Col. Hidalgo, Monterrey,
Nuevo Leon, Mexico, C.P. 64290
T: +52 1 81 2871 2871
sales@goodwe.com / soporte.latam@goodwe.com
Note: The above contact information is subject to change without notice. For details, refer to the
company's official website www.goodwe.com
340-00432-01
Offical Website
GOODWE (China)
No. 90 Zijin Rd., New District, Suzhou, 215011, China
T: +86 (0) 512 6958 2201
sales@goodwe.com (sales)
service@goodwe.com (service)
GOODWE (Brazil)
Rua Abelardo 45, Recife/PE, 52050-310
T: +55 81 991239286
sergio@goodwe.com
servico.br@goodwe.com
GOODWE (UK)
6 Dunhams Court, Dunhams Lane, Letchworth
Garden City, SG6 1WB UK
T:+ 44 (0) 333 358 3184
enquiries@goodwe.com.uk / service@goodwe.com.uk
GOODWE (Italy)
Via Cesare Braico 61, 72100 Brindisi, Italy
T: +39 338 879 38 81; +39 831 162 35 52
valter.pische@goodwe.com (sales)
operazioni@topsenergy.com; goodwe@arsimp.it (service)
GOODWE (Australia)
Level 14, 380 St. Kilda Road, Melbourne,
Victoria, 3004, Australia
T: +61 (0) 3 9918 3905
sales@goodwe.com / service.au@goodwe.com
GOODWE (Korea)
8F Invest Korea Plaza, 7 Heoleung-ro
Seocho-gu Seoul Korea (06792)
T: 82 (2) 3497 1066
sales@goodwe.com / Larry.Kim@goodwe.com
HT SERIES USER MANUAL
SOLAR INVERTER
Photovoltaic
Grid-Tie Inverter
Rev 1.1
2020-11-11

Advertisement

Table of Contents
loading

Summary of Contents for Goodwe HT Series

  • Page 1 GOODWE (China) No. 90 Zijin Rd., New District, Suzhou, 215011, China T: +86 (0) 512 6958 2201 sales@goodwe.com (sales) service@goodwe.com (service) HT SERIES USER MANUAL GOODWE (Germany) GOODWE (Brazil) Fürstenrieder Str. 279a 81377 München, Germany Rua Abelardo 45, Recife/PE, 52050-310...
  • Page 2: Table Of Contents

    1 Symbol Definition ....................01 2 Safety Instructions ....................02 3 Product Introduction ..................03 3.1 Product Naming Rules ......................03 3.2 Packaging Information......................04 3.3 Appearance Introduction......................05 4 Installation Method ....................07 4.1 Installation Instructions......................07 4.2 Select Installation Location......................
  • Page 3: Symbol Definition

    • Ensure that the DC input voltage is less than the maximum input voltage of the inverter, otherwise the inverter will be damaged. GOODWE will not be responsible for this damage, and the warranty will be void.
  • Page 4: Product Introduction

    Model Description (taking GW100K-HT as an example): 1. GW - abbreviation for company name 2. 100K - rated output power The grid structures supported by HT series 136K are TN-S, TN-C, TN-C-S, TT, IT, as shown in the 3. HT - model code diagram below: 3.2 Product Purpose...
  • Page 5: Appearance Introduction

    3.3 Appearance Introduction Name Description After opening the package, check the product to confirm whether it is consistent with the Used to safely disconnect the DC input as required. When the specifications of the inverter you purchased. The appearance of the product is shown in the input and output meet the requirements, the inverter will run diagram.
  • Page 6: Installation Instructions

    4 Equipment Installation 4.3 Inverter Installation 4.1 Installation Instructions 4.3.1 Wall Installation Procedure: • The installation height shall be parallel to the line of sight for easy operation and maintenance. Step 1: Use the back hanger for Step 2: Use the expansion screws in the positioning.
  • Page 7: Electrical Installation

    4.4 Electrical Installation 4.3.2 Bracket Installation Procedures: 4.4.1 AC Terminal Connection 1. Measure the voltage and frequency of the grid-tie connection point to confirm that it meets the Step 1: Use the back hanger for Step 2: Use the expansion screws in the grid-tie specifications of the inverter.
  • Page 8 Step 5: Tighten the screws, install the fireproof mud, and finally put on the cover. Step 2: Firstly, trim the waterproof silicone ring according to actual needs, Then pass the AC cord through the waterproof silicone ring. Use scissors to trim and adjust Waterproof silicone ring aperture Note: To ensure the machine is airtight, adjust the aperture of the waterproof...
  • Page 9 4.4.2 AC circuit breaker and leakage current protection device Step 2: Take the DC terminal from the accessory pack, turn the nut to remove it, and take To ensure that the inverter can be safely and reliably disconnected from the grid, install a circuit out the waterproof rubber ring.
  • Page 10 4.4.4 External Ground Terminal Connection Step 5: Insert the crimped DC cable into the DC terminal, then insert the waterproof rubber According to EN50178 requirements, the inverter must have a protective ground connection. The ring into the DC terminal and tighten the nut. user must connect this terminal to a protective ground wire while installing the equipment.
  • Page 11: Communication Installation

    4.5 Communication Installation Step 2: Choose RS485 shielded twisted pair wire and strip it as shown in the diagram below, then connect the terminal and crimp it tightly. 4.5.1 RS485 communication 6.5mm This function is only applicable to RS485 models. The RS485 port of the inverter is used to connect to the data collector, and the total length of the connecting cable must not exceed 1000m.
  • Page 12 After the communication configuration is completed, scan the QR code on the back of this method of WiFi communication module is shown in the diagram below. manual or visit www.sems.com.cn. Download the goodwe.cloudview APP and complete the Note: The communication module must be aligned and inserted vertically into the communica- registration to use the cloud monitoring function.
  • Page 13: Operating Instructions

    5.2 Description of Display Screen and Buttons 5 Operating Instructions 5.1 indicator Description Note: For inverters without display, scan the QR code on the left to download Model without display and install the SolarGo App, and complete the corresponding configuration operations in the App. SolarGo App Setting the country of safety regulations: If the LCD displays “GW100K-HT Power = XXXXX watts”...
  • Page 14 (5) Menu Introduction set by short pressing the button. To switch to the next digit, long press for 2 seconds. If you *After the machine is powered on, the default display is the first level menu. entered the second level screen without making any changes, and did not press the button *The status display is the first menu of the first level menu, which displays the current status of within 20 seconds, the display backlight will go off...
  • Page 15: Failure Information

    5.3 Failure Information First level menu Second level menu Grid-tie power generation Long press for 2s 50Hz grid voltage Power = XXXXX watts The error message in the following table will be displayed on the screen when the abnormal Short press Daily power generation: Long press for 2s Locked...
  • Page 16: Frequently Asked Questions

    6 Frequently Asked Questions Type Display Troubleshooting Under normal conditions, the inverter requires no maintenance. If the inverter cannot work normally, refer to the following instructions: Relay Check Failure • When a problem occurs, the red light on the operation panel will light up, and relevant information will be displayed on the APP.
  • Page 17: Product Specifications

    7 Technical Data Interpretation of overvoltage levels: Overvoltage level I: Connect the product to a circuit with measures to limit instantaneous 7.1 Product Specifications overvoltage to a relatively low level. Overvoltage level II: Energy-consuming equipment powered by fixed power distribution devices. Technical Data GW100K-HT GW110K-HT...
  • Page 18: Schematic Diagram Of Main Circuit

    DC Switch 1 PV4+ DC EMI MPPT4 PV4- PV5+ DC EMI MPPT5 PV5- Output The external fan of the HT series inverter needs to be cleaned with a vacuum cleaner every PV6+ DC/AC Inverter Filter DC EMI MPPT6 Filter PV6- circuit DC Switch 2 year.
  • Page 19: Electrical Connection Check

    Startup sequence 1. Turn the circuit breaker on the AC side to the "ON" position; 2. Turn the DC switch of the inverter to the "ON" position. Shutdown sequence 1. Turn the circuit breaker on the AC side to the "OFF" position; 2.

This manual is also suitable for:

Gw100k-htGw110k-htGw120k-htGw136k-hthGrid-tie ht seriesGrid-tie gw100k-ht ... Show all

Table of Contents