Maintenance Instructions; Access To The Components For Inspection - eka MILLENIAL MKF 464 TS Installation And Maintenance Manual

Electronic ovens with touch screen
Table of Contents

Advertisement

4. Maintenance instructions

A periodic check (at least once a year) of the appliance contributes to extending its service life and assures
proper operation.
Any maintenance operation on the appliance must only be done by highly qualified personnel trained in the
operations being performed and authorised by
with the safety regulations in force in the country where the appliance is installed, pursuant to the
regulations relative to plants and to workplace safety.
Before carrying out any maintenance on the appliance it must be disconnected from the mains and allowed
to cool down.
The Manufacturer is not responsible for any appliance faults caused by defective maintenance.

4.1 Access to the components for inspection

Removing the left side:
-
Magnetic door sensor (right opening)
-
Electronic components box
-
Cooking chamber probe
-
Terminal board 12V (accessory cable connection)
-
Contactors
-
Anti-interference filter (if any)
Removing the back;
-
Tangential motor (on the back)
-
Circular resistors
-
Radial motors/Encoder motor
-
Dryer motor
-
Contactors
-
Power supply terminal board
-
Safety thermostat
-
Capacitors
-
Humidification solenoid valve
-
Humidification piping/fittings unit
for models "V TS" and "V C TS" add:
-
Steam generator
-
Steam generator safety thermostat
-
Steam generator "discharge" solenoid valve
-
Steam generator "charge" solenoid valve
-
Steam generator piping/fittings unit
Removing the right side:
-
Magnetic door sensor (left opening)
-
Peristaltic washing pump
-
Washing solenoid valve
-
Washing piping/fittings unit
Pulling the LED bar protection box (on the door):
-
LED Bar
-
Display
-
Encoder display
11
. Operations must be carried out in accordance
TECNOEKA

Hide quick links: