Connection To The Water Mains - eka MILLENIAL MKF 464 TS Installation And Maintenance Manual

Electronic ovens with touch screen
Table of Contents

Advertisement

3.10 Connection to the water mains

The appliance must be supplied with drinking water at a maximum temperature of 30°C.
The water pressure must be between 100 and 200 kPa (1.0 -2.0 bar).
If the mains pressure exceeds 2.0 bar, install a pressure reducer upstream of the appliance.
If the value is lower than 1.0 bar use a pump to raise the pressure.
3.10.1 Water inlet for humidification / steam
The appliance is equipped with a standardised flexible hose (1.5 metres) with threaded ¾" female fittings
and relative gaskets (Fig. 1). Old joints must not be re-used.
The appliance must be supplied with softened drinking water with hardness between 0.5°f and 3°f. It is
obligatory to use a softener to reduce the formation of limescale inside the cooking chamber.
THE
MANUFACTURING COMPANY DISCLAIMS ANY LIABILITY FOR DIRECT OR INDIRECT DAMAGE CAUSED TO THE HOOD
DUE TO FAILURE TO COMPLY WITH THIS DIRECTIVE.
The connection to the water mains must be set up through the ¾" threaded solenoid valve located on the
back (at the bottom) of the appliance (see the attached "Technical Data Sheet"), using the supplied flexible
hose, with a mechanical filter and stopcock installed in between (before connecting the filter, drain off a
certain amount of water to flush any dirt out of the hose).
Fig.1
Warning
Any damage caused by limescale or other chemicals contained in the water are not covered by warranty.
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents