4. MAINTENANCE INSTRUCTIONS

A periodic check (at least once a year) of the appliance contributes to extending its service life and assures
proper operation.
Any maintenance operation on the appliance must only be done by highly qualified personnel trained in
the operations being performed and authorised by
accordance with the safety regulations in force in the country where the appliance is installed, pursuant to
the regulations relative to plants and to workplace safety.
Before carrying out any maintenance on the appliance it must be disconnected from the mains and allowed
to cool down.
The Manufacturer is not responsible for any appliance faults caused by defective maintenance.

4.1 Access to the components for inspection

Removing the left side:
-
Magnetic door sensor (right opening)
-
Electronic components box
-
Cooking chamber probe
-
Terminal board 12V (accessory cable connection)
-
Contactors
-
Anti-interference filter (if any)
Removing the back;
-
Tangential motor (on the back)
-
Circular resistors
-
Radial motors
-
Contactors
-
Power supply terminal board
-
Safety thermostat
-
Capacitors
-
Humidification solenoid valve
-
Humidification piping/fittings unit
Removing the right side:
-
Magnetic door sensor (left opening)
-
Peristaltic washing pump
-
Washing solenoid valve
-
Washing piping/fittings unit
Pulling the LED bar protection box (on the door):
-
LED Bar
-
Display

4.2 Safety thermal device

The appliance is equipped with a (manually reset) safety thermostat, to protect against excessive and
hazardous overheating which might accidentally occur inside it. If the safety thermostat trips, the power
supply to the appliance is cut off.
The safety thermostat is located at the back (bottom) of the appliance (see the attached "Technical Data
Sheet"); to reset it after it has tripped, unscrew the protective cap using an appropriate tool and press the
"reset" button all the way. Replace the protective cap so that it cannot be unscrewed without the use of a
tool.
Important
The safety thermostat should only be reactivated after eliminating the functional anomalies that caused it
to trip. This can only be done by a Service technician.