Noise Sensitivity - Nokia Mobile Phones NSE-5 Series Service Manual

Cellular phones
Table of Contents

Advertisement

PAMS
Technical Documentation
Same channel is used both for transmission and receiving. This updates
same parameter as Channel in the RF–Controls dialog.
Channel 1,2,3,4,5,6 edit box (ALT+1,2,...):
Channels for monitoring are specified with these six selections. All
GSM/PCN channel numbers can be used. If more than one selection has
same number, the monitoring channel list (neighbour list) will have less
than 6 selected channels. The minimum number of monitoring channels is
one (all channels have same value). The monitoring channel can also
have same value as normal operating channel.
The first monitoring channel updates same parameter as Monitoring
Channel in the RF–Controls dialog.
Apply button (ALT+A):
Validates and sends entered data to ME.
Set Defaults button (ALT+S):
Sets current values as default Call Simulation values.
Get Defaults button (ALT+G):
Gets default Call Simulation values as current values.
Noise Sensitivity... command
A GSM/Signal generatorand an antenna cable is needed for this test. The
active band must be set to the GSM band.
Activation
Alt, E, N
Command is used for noise sensitivity measurement.
The next automatic selections are made when this tuning function is
activated:
- Active unit = RX
- Operation mode= Burst
- AGC value = 81 dB
Before function opens Noise Sensitivity dialog application prompts:
Issue 1 07/99
Status Bar Text
Initialising local mode...;
Noise Sensitivity; Set test on...;
Service Software Instructions
Page 67