The next table shows the dialog's properties on different situations:
ACTIVE UNIT = TX:
TX Data Type: Updated
AGC values: Greyed
Monitoring Channel: Greyed
OPERATION MODE = BURST:
TX Power Level: Updated
Continuous Mode Channel: Greyed
Channel: Updated
ACTIVE UNIT = RX:
TX Data Type: Greyed
TX Power Level: BASE, Greyed
Operation Mode = Burst:
AGC values: Greyed
Continuous Mode Channel: Greyed
Channel: Updated
Monitoring Channel: Updated
OPERATION MODE = CONT:
AGC values: Updated
Continuous Mode Channel: Updated
Channel: Greyed
Monitoring Channel: Greyed
RSSI Reading... command
A GSM/PCN signal generator and an antenna cable is needed for this
test.
Activation
Alt, E,E
Command opens RSSI Reading dialog:
Dialog mode: modal
RSSI value is read continuously until user presses ESC–key or Close
button to cancel reading.