PAMS
Technical Documentation
Testing
The Testing sub menu offers functions for ME testing.
A GSM/PCN tester and an antenna cable is needed for this test.
RF Controls... command
Activation
Alt, E,R
This function is used for RF testing.
Command opens RF Controls dialog, which contains data for testing and
adjustments.
Dialog mode: modal
RF Controls dialog has following items:
Active Unit group:
RX radio button (ALT+R):
When RX is selected, the next functions are made:
Data transmission is deactivated
- TX power is deactivated
- Rf operation mode is continuous,
AGC is controlled
Issue 1 07/99
Status Bar Text
RF Controls; Set test on...;