Nokia Mobile Phones NSE-5 Series Service Manual page 156

Cellular phones
Table of Contents

Advertisement

NSE–5
Service Software Instructions
Front End On check box: (ALT+E)
This selection allows user to change whether the Front End amplifier is
On or Off. The Front End On check boxis disabled (greyed) when the
operation mode is burst.
AGC edit box (ALT+G):
This selection allows user to edit AGC value in dB
AFC edit box (ALT+F):
This selection allows the user to edit the AFC slope in DAC values.
AGC value is shown only when its value is controlled by PC. When Ac-
tive Unit has value RX and Operation Mode is continuous, AGC is con-
trolled by PC except when next adjustment functions are activated:
RSSI Calibration
AFC Diagram
Apply button (ALT+A):
Accepts entered values and validates them. After validation application
sends corresponding messages to ME. Closes dialog and updates Info
Window.
Note Active Unit and Operation mode are not send with because they are activated
immediately.
Set Defaults button (ALT+S):
Sets the current values as default Rf Control values.
Get Defaults button (ALT+U):
Gets default Rf Controls values as current values.
The next automatic selection is made when Quick testing function is
ended:
Active Unit = RX
Update RF Information window
Page 56