Installation; Connect Venting - Valor AutoFire G4 Installation Manual

Direct vent gas fireplace insert gas fireplace natural gas 785yn propane gas 785yp
Table of Contents

Advertisement

Installation

Connect Venting

IMPORTANT: This appliance's venting system is room
sealed and therefore, does not require room air to be used
in the combustion process.
1. Rough-in two 3" diameter vent liners into the existing
chimney system from the roof. Be careful not to tear
or damage the liners in the process. It may be easier to
install both liners at the same time rather than one at
a time. Leave plenty of liners at the bottom to facilitate
the connection of the liners to the vent slider. It is best
to leave the top termination until later.
Designate and mark the top and bottom of one liner
as "EXHAUST" to avoid confusion later.
2. Release the two screws retaining the vent slider to the
front of the fi rebox. Remove the slider from the fi rebox
by sliding it towards the back of the fi rebox.
3. Fit the two liners ensuring that the exhaust liner is
connected to the identifi ed "EXHAUST" vent collar.
Secure liners to collars with hose clamps (included)
and 2 tapping screws per liner.
4. Slide the fi rebox onto the vent slider in the cavity tak-
ing care not to damage the liners. Make sure that the
rear edge of the slider is hooked over the cleat on the
fi rebox. Secure the vent slider to the front of the fi re-
box with two screws
removed earlier.
5. From the roof, pull
the liners and fi t the
fl ashing.
6. Fit the terminal cap
ensuring that the
exhaust liner is
connected to the
exhaust vent collar.
Secure with screws.
7. Seal the terminal
and fl ashing from
water penetration as
required.
 WARNING
Failure to position the parts in accordance
with these diagrams or failure to use
only parts specifically approved with this
appliance may result in property damage
or personal injury.
16
Vent slider
cleat
2
4
Connect Venting
7
6
5
1
3