Installer manual Autotrol 368 (604-606) - Programming
6

Programming

Info
After 5 seconds without keypad input, the unit returns to normal operation mode and
display the time of day.
Memory retention in case of power failure : the controller stores the time of day
without battery in case of power failure. All others programmed parameters are stored
in the nonvolatile (Novram) memory and are stored during power failure. The storage
time in the flash memory is about 99 years.
has two different functions according to the controller used:
• For 604 controllers: the function is the day interval setting.
• For 606 controllers: the function is the volumetric capacity setting.
6.1

Display

1. Digits
2. Flow indicator
3. Delayed regeneration
indicator
6.2

Commands

1. Camshaft indicator
2.
 - Manual regeneration
button
32 / 60
Two digits used to display the time, program value or error codes.
The flow indicator blinks ON and OFF when water flow turns the
meter.
When this dot is displayed, it means that a delayed regeneration is
programmed.
A column of windows provides a visual indicator of the camshaft
rotation.
The manual regeneration button when pressed initiates either a
delayed regeneration or immediate regeneration.
Ref. MKT-IM-007 / D - 09.10.2020