Suspending manual regeneration
Manual regeneration may be suspended at any time by executing one of the following:
• Setting the function cancellation lever to the unlock position (safety bar out).
• Operating the engine accaleration button.
• Pressing the switch.
If operation continues when manual regeneration stops for a long time, the diffuser may become faulty.
Move to a safe place as quickly as possible and execute regeneration.
If regeneration is suspended for a long time, the engine problem warning lamp goes on and the diffuser needs to be
repaired.
1. In manual regeneration
• The orange lamp is lit.
• The following messages are displayed cyclically.
Manual DPD Re-gen
Do not operate
2. Carry out one of the following operations.
• Set the function cancellation lever to the unlock position (safety bar out).
• Operate the engine acceleration button.
• Press the switch.
3. Manual regeneration stops.
• The orange lamp blinks.
• The following message is displayed.
Push DPD switch to activate
4. Move the machine to a safe place with no combustible objects and retry manual regeneration.