Travel Reduction Gears - Case CX145C SR Operator's Manual

Crawler excavator
Table of Contents

Advertisement

Travel reduction gears

Service specifications
Oil level check: Every 250 hours
Oil drain: Every 1000 hours (after the first 250 hours during the run-in period)
Oil capacity (per reduction gear): 2.1 l (0.6 US gal)
Type of oil: (Refer to page 6-5)
Level
1. Park the machine on flat, horizontal ground.
2. Move the machine so that plug (1) is in the lowest
possible position.
3. Stop the engine and remove the ignition key.
4. Slowly loosen the plug (3) to release any residual pres-
sure.
5. Remove the plug (2) and check the oil level. The level
must come up to the bottom edge of the port (2). If
required, remove the plug (3) and top up through this
port until oil comes up to the bottom edge of the port
(2).
6. If necessary, replace the seals of plugs (2) and (3) then
replace the plugs.
7. Repeat Steps 2 to 6 for the other travel reduction gear.
8. Travel slowly with the machine and make sure there
are no leaks.
6 - MAINTENANCE
6-54