Maintenance; Replacement Of Sensors - Roland R1000 Series Manual

Double sheet detector
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0046191 / Rev. 1.12
10

Maintenance

Pos: 73 /Doppelblech/Geräte/E20 Bus/10 Wartung/Wartung allgemein @ 0\mod_1173429782578_501.docx @ 3329 @ @ 1
Generally the Double Sheet Detector R1000 E20 requires no special or regular maintenance.
If new types of sheet metal and dimensions are to be processed, then a new teach-in for new
programs to be stored is necessary, see also section "7.6 Program parameter 7: Teach-in".
In the following cases a new teach-in for all programs becomes required:
If a sensor exchange was not done according to the instructions in the following section
"10.1 Sensor exchange"
Pos: 74 /Doppelblech/Geräte/E20 Bus/10 Wartung/Austausch von Sensoren, Gerät und Sicherungen @ 0\mod_1173281042593_501.docx @ 3274 @ 222 @ 1
10.1

Replacement of sensors

In order to further use the taught programs, the following must be observed:
Before the sensor is removed, its installation position must be exactly documented.
This applies especially to the installation position with regard to the measuring axis.
The original installation position in all directions has to be restored.
This applies especially to the gaps between the sheets.
After having exchanged a sensor, the zero adjust must be performed again.
Proceed as follows:
For an E20 or E20-4P control unit with one sensor:
1
Ensure that no sheet is in front of the sensor
2
Press the MENU key, select "change" and confirm with the ENTER key
3
Enter the password
4
Change to "program parameter" and confirm with the ENTER key
5
Ensure that no sheet is in front of the sensor
6
Change to "zero adjust", select "on" and confirm with the ENTER key
7
The unit shows "Remove sheet", perform and confirm with the ENTER key
8
Control unit shows "zero adjust: active", then "zero adjust: off"
9
Exit the programming with the MENU key
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
Note
If the original sensor positions cannot be restored, then the teach-in
has to be repeated for all programs.
Manual
Maintenance
135

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E20

Table of Contents