B0046191 / Rev. 1.12
2.3.4
Sensor P128GPPS
Fig. 5: Sensor P128GPPS
Technical data
Measuring range
Ambient temperature:
Class of protection:
Weight:
Sensor cable:
1)
Related to single sheet thickness
Pos: 17 /Doppelblech/Geräte/E20 Bus/2 Technische Daten/Sensordaten (Messzeit) @ 0\mod_1173874538093_501.docx @ 3896 @ 2 @ 1
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
1)
:
1.0 – 12.0 mm
0 – 60 °C
IP65
approx. 7.0 kg
pluggable
Manual
.04 - .47 inch
30 – 140 °F
15.43 lbs