Start-up
Program parameter 3: Specifying the nominal thickness of the sheet to be measured.
program param.
nom. thick.:
Fig. 63: Adjusting the nominal thickness
Here the nominal thickness of the sheet to be measured is specified. Normally, the nominal
thickness is the sheet thickness used for teach-in.
Program parameter 4: Setting the percentage threshold of the upper limit value.
program param.
up
150%
Fig. 64: Adjusting the upper limit
Value range: between 100% and 150%, with simultaneously displaying the absolute limit value.
The maximal settable absolute limit depends on the sensor:
•
P42, P42A:
•
P30, P36:
•
P75:
•
P75V:
•
P128:
Program parameter 5: Setting the percentage threshold of the lower limit value.
program param.
low:
50%
Fig. 65: Adjusting the lower limit
Value range: between 0% and 99%, with simultaneously displaying the absolute limit value.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
112
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
3
0.90mm
Note
A change of the nominal thickness deletes the values determined
during teach-in. A new teach-In is required.
4
1.350 mm
5 mm (.197 in.)
3 mm (.118 in.)
6,8 mm (.268 in.)
9,2 mm (.362 in.)
14 mm (0.551 in.)
5
0.450 mm
Manual
B0046191 / Rev. 1.12