B0046191 / Rev. 1.12
2.3.2
Sensor P42AGS
P42AGS
All dimensions are in mm. Length tolerance ± 0.8 mm, all other dimensions ± 0.2 mm
Fig. 3: Sensor P42AGS
Technical data
Measuring range
Ambient temperature:
Class of protection:
Weight:
Sensor cable:
Measurable ohmic resistances
Pin 1-2:
Pin 4-3:
Pin 1-4:
Pin 2-3:
1)
Related to single sheet thickness
2)
Pins are not connected to the sensor housing
Pos: 15 /Doppelblech/Sensoren/P-Sensoren/P75/P75VGS Techn. Daten @ 0\mod_1138636403405_501.docx @ 1248 @ 3 @ 1
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
with straight cable plug
2)
:
0.2 – 4.0 mm
0 – 60 °C
IP65
approx. 0.42 kg
pluggable
2)
:
Approx. 20 Ω
0 Ω
Manual
P42AGS
.01 - .16 inch
30 – 140 °F
0.93 lbs
Technical data
P42AGS
with 90° angled cable plug