Roland R1000 Series Manual page 116

Double sheet detector
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

Start-up
System parameter 3: Selecting the dimensions for output via fieldbus (mm / inch).
system parameter
bus readout:
Fig. 74: Selecting the dimensions for the fieldbus output
When changing the measurement dimensions, then the sheet metal thicknesses of the stored
program parameters are also converted into the new dimension. As in the previous parameter,
%mm and %inch are also available.
System parameter 4: not available (reserve).
system parameter
not available
Fig. 75: Reserved system parameter
System parameter 5: Setting the bus address.
system parameter
bus address:
Abb. 76: Setting the fieldbus address
Profibus:
ControlNet:
DeviceNet:
CanOpen:
ProfiNet IO:
CC-Link:
EtherNet/IP
EtherCAT
This system parameter is only for EtherNET/IP
system parameter
EthernetIP DHCP:
Fig. 77: Setting DHCP
system parameter
IP:
192.168.
Fig. 78: Setting IP-address
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
116
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
3
mm
4
5
1
1 - 125
0 - 99
0 - 63
1 - 127
– –
1 – 62
– –
– –
Note for Profibus: If this adjustment is to be made in the hardware, then the bus
address can be set with the rotary switches inside the
enclosure (1 to 99). If this adjustment is to be made via
software, then the rotary switches must be turned to
address 0.
5
no
5b
0. 10
Manual
If DHCP is switched on, the IP-setting will done via
DHCP. If DHCP switched off, must the IP-adress,
SubNET and Gateway be selected.
Here is the IP-address selected.
B0046191 / Rev. 1.12