Filters Maintenance; Fan Maintenance - Salda Smarty 2XV 1.1 Mounting And Installation Instruction

Table of Contents

Advertisement

6.4.

FILTERS MAINTENANCE

• In order to remove the filters, open filter cover by pulling the strap and take off the filters. Use Coarse 65% filters or optionally ePM1 70% filter
for outdoor air filtration and Coarse 65% filter for exhaust air filtration.
• Dirty filters increase air resistance, airflow into the room.
Figure 6.4.1. Smarty 2XV
After changing the filters, please reload the filter timer. The instruction on reloading can be found in the control panel opera-
tion manual or on our website www.salda.lt
Operation of the unit without filters is not allowed.
Change the filters every 3-4 months or according to the notification on the control device.
6.5.

FAN MAINTENANCE

• Fan maintenance should be performed by experienced and trained staff only.
• The fan should be inspected and cleaned at least once per year.
• Prior to commencing any maintenance or repairs , make sure the fan is disconnected from the power source.
• Observe staff safety regulations during maintenance and repairs.
• The motor features a heavy-duty ball bearing design. The motor is completely sealed and grease- free.
• Detach the fan from the unit.
• The impeller should be particularly checked for built-up material or debris that may cause an imbalance. Excessive imbalance may lead to ac-
celerated wear on motor bearings and vibration.
• Clean impeller and inside housing with mild detergent, water and damp, soft cloth.
• Do not use high-pressure cleaner, abrasives, sharp tools or caustic solvents that may scratch or damage the housing and impeller.
• Do not plunge the motor into any fluid while cleaning the impeller. Make sure the impeller's balance weights are not moved.
• Make sure the impeller is free of any obstacles.
• Install the fan back into the unit. Connect fan power and control signals.
• In case the fan after maintenance does not automatically start up or stop, contact the manufacturer. Malfunction of the fan can be identified by the
pressure in the system (when pressure switches are connected). In case of any fault in the fan motor, a notice will appear on the control panel.
Prior to commencing any maintenance or repairs, make sure the unit is disconnected from the power source.
• Remove the fans connectors from the control board or fan housing. Supply air fan connects to control board's X15, X2, X4 connectors. Extract air
fan connects to control board's X16, X2, X4 connectors. Smarty 4XV F2 fans can be disconnected by unplugging X32, X33 connectors located
on the fans housing.
Note:
• X2 and X4 are same for both fans.
• Reassembling must be executed in the reverse order.